Related Factors Affecting Ultraviolet Germicidal Effect

[Irradiation intensity and irradiation time] The lower the irradiation intensity of the ultraviolet lamp, the worse the bactericidal effect. When the intensity is lower than 70Lw.cm2, even if it is irradiated for 60 minutes, the killing rate of bacterial spores cannot meet the qualified requirements. The irradiation dose of ultraviolet light increases with the increase of irradiation intensity. When the irradiation dose is equal, the sterilizing effect of different irradiation intensities is similar 1-3. Therefore, the disinfection technical specification stipulates that the irradiation intensity of ultraviolet disinfection lamps should not be lower than 70Lw. cm2, when the disinfectant is unknown or to kill a variety of viruses and bacteria, the irradiation dose should not be lower than 100Lw.s.cm2. The irradiation intensity of the ultraviolet lamp is affected by voltage, temperature, irradiation distance, irradiation angle, etc. At the same time, attention should be paid to the cleanliness and service life of the lamp.

Experiments have shown that the intensity of the ultraviolet lamp decreases by 15-20Lw.cm2 when the voltage drops by 10V, and the ultraviolet lamp cannot work when the voltage is below 190V. Under the condition of a voltage of 220V and a room temperature of 0-40°C, the intensity of ultraviolet radiation increases with the increase of room temperature. For example, when the lamp temperature drops from 27°C to 4°C, the output will drop by 60%-80%. When the voltage is 190-240V and the room temperature is 16-35°C, the ultraviolet irradiation intensity has a linear relationship with the voltage and room temperature Y=-325.12+2.014X1+0.72X24,5.

The relationship between the intensity of ultraviolet radiation and distance is E=97.72, and the effective distance of ultraviolet radiation is 0.7-2.4m. Outside the vertical line at both ends of the ultraviolet lamp, the ultraviolet intensity attenuates significantly with the increase of the angle, and is 0 near the center line outside the ultraviolet. Therefore, during ultraviolet disinfection, multiple lamps are used at right angles to offset dark areas6,7.

[Types of microorganisms] Various microorganisms have different tolerances to ultraviolet rays. Fungal spores are the most resistant to ultraviolet rays, followed by bacterial spores, and the worst are reproductive-type microorganisms. Generally, bacterial spores are 2-7 times more resistant than their propagules.

There are also differences in the resistance to ultraviolet rays between different strains of the same species, different cultures of the same bacteria and different generations. [The number of microorganisms, the influence of suspended carriers and organic matter] Experiments have shown that the more bacteria that are contaminated, the greater the dose of ultraviolet radiation required. Bacteria attached to dust and suspended in the air are more resistant than bacteria liquid aerosols, because the penetration of ultraviolet rays is poor, air dust can absorb ultraviolet rays and reduce the sterilization rate, when the air contains 800-900 dust particles. cm3, the bactericidal efficiency can be reduced by 20%-30%; the presence of peptone, eggs, milk, blood, serum, etc. can increase the resistance of microorganisms to ultraviolet rays, because adding organic solvents to DNA or methylthymine solutions can make For base stacking, Wacker et al. studied the effect of different organic solvents on the formation of thymine dimers, and found that the greater the non-polarity, the smaller the dimerization.

[Affecting temperature] Most microorganisms (except Micrococcus) are very sensitive to ultraviolet radiation at low temperatures, because under this condition, the number of thymine dimers is significantly reduced, and the accumulation of thymine photoproducts will affect the growth of microorganisms. Repair, and temperature changes also affect the intensity of UV rays. If the temperature is too high or too low, it will affect the disinfection effect. Generally, the appropriate temperature is 20-40°C7, and some people think that the appropriate temperature is 10-25°C. 【Moderate effect】 There is no consensus on the effect of humidity on ultraviolet sterilization.

Ri2leyr believes that when the relative humidity is above 60%-70%, the killing rate of microorganisms will drop sharply, the most suitable is 40%-60%, and more than 80% may even have an anti-activation effect. When the relative humidity increases from 33% to 56%, the bactericidal efficiency can be reduced to the original 1.3. Others think that the impact of humidity on the sterilization rate may be manifested in three aspects: ① Due to the high relative humidity, the particles in the air increase and are easy to capture during sampling, which makes the sterilization effect appear to decline.

②The increase of particles weakens the penetration of radiation into cells, thus reducing the killing effect. ③When the relative humidity is 60%-70%, the water content of bacteria in the air is 30g.100g bacteria, which is called the critical water content. Ultraviolet radiation energy transfer can destroy the conjugation relationship of bacterial macromolecules. This effect is likely to occur in bacteria with critical water content and dehydration. Therefore, the sterilization efficiency of ultraviolet rays is generally low under high humidity conditions.

The protective effect of inositol and some compounds on microbial aerosol is precisely because they replace the bound water lost by bacteria. Poolking is the best swimming pool equipment manufacturer and supplier in China. Poolking exists to provide the highest quality swimming pool equipment while offering competitive pricing..

우리와 연락을 취하십시오
추천 기사
소식 애플리케이션 제품 운송
아틀란티스 싼야의 풀킹 상업용 모래 필터

해양 문화는 이 호텔의 주요 특징입니다. 13500톤의 천연해수를 보유한 앰버서더 라군은 280여종의 담수어와 해양생물을 보유하고 있다[4]. 호텔 내에는 '로스트 스페이스' 수족관이 있다. 관광객들은 상어, 가오리, 해파리, 거꾸로 된 물고기, 바다 장어, 거대 뼈혀 물고기 등 280종 이상의 생물을 관찰할 수 있습니다. 그들은 또한 다이빙 프로젝트에서 이국적인 해양 생물과 함께 춤을 출 수도 있습니다. 또한 호텔은 20만 제곱미터에 달하는 면적을 차지하는 물의 세계도 만들어냈습니다. 일년 내내 운영되는 워터파크로, 수십 개의 탑 슬라이드, 스피드 래프팅, 어린이를 위한 워터펀파크 등이 갖춰져 있습니다. 호텔에는 유럽식 셀프서비스, 중국식 셀프서비스, 일본식 요리 등 세계 각국의 요리를 선보이는 21개의 글로벌 구르메 레스토랑이 있습니다. 관광객들은 하이난에서 세계 음식 문화를 느낄 수 있습니다.
----풀킹은 세계적인 수준의 생산 기계를 여러 대 사용하여 제품을 생산하며, 각 제품에 엄격한 품질 관리 시스템을 적용합니다. 작은 결함도 절대 용납하지 않습니다. 좋은 품질의 제품뿐만 아니라 고객에게 신속하고 만족스러운 애프터서비스를 제공합니다. 고객 여러분께 깨끗한 물과 편안한 서비스를 제공해 드립니다. 풀킹의 제품이 다른 제품과 품질은 같지만 가격이 높다면, 풀킹은 어떻게 살아남을 수 있을까요? 하지만 풀킹은 다른 경쟁 업체들을 물리치고 시장 점유율을 높일 수 있습니다. 풀킹은 최고의 선택입니다!
---Poolking은 전문 품질 관리팀을 통해 모든 제품이 포장 전 100% 검사를 거칩니다. 예를 들어, 필터 내부 탱크가 출고되면 보빈 와인딩 전에 1차 수질 검사를 실시합니다. 모든 연결부 또는 맨홀 및 사이트글라스 설치 후 2차 수질 검사를 실시합니다. 포장 과정에서 품질 관리팀은 와인딩, 넥, 내부 레진 등 모든 세부 사항을 검사하여 누수 및 결함이 없는지 확인합니다.
최고의 품질 생산 환경 공장 공급업체

풀킹 최고최고품질 생산환경 공장공급업체


풀킹 최고품질 생산환경 공장
약 5~10일 후 또는 필터의 펌프 측에 있는 압력 게이지의 판독 값이 마지막 역세척 이후 약 0.2bar 증가하면 다음과 같이 필터를 역세척합니다.1. 펌프를 멈춥니다.2. 흡입 및 복귀 라인의 밸브를 닫습니다.3. 펌프의 덮개를 열고 필터 개스킷을 비웁니다.4. 덮개를 다시 장착합니다.5. 배수구의 밸브를 엽니다.6. 레버를 BACKWASH로 돌립니다.7. 흡입 및 복귀 라인의 밸브를 엽니다.8. 펌프를 시작합니다.사이트 글라스의 물이 깨끗해질 때까지 약 1~2분 동안 필터를 헹굽니다.주의: 모든 전기 히터는 꺼야 합니다.9. 펌프를 멈춥니다.10. 레버를 RINSE로 돌리고 펌프를 시작한 다음 약 15~30초 동안 헹굽니다.펌프를 멈추고 레버를 FILTER로 돌립니다.이것이 정상적인 작동 위치입니다. 11. 배수 밸브를 닫고 펌프를 가동하세요. 전기 히터가 있다면 켜세요.
수영장 펌프를 프라이밍하는 방법은?

수영장 펌프는 수영장의 중앙 순환 시스템입니다. 이것이 없다면 수영장 물은 수영하기에 적합하지 않을 것입니다.
데이터 없음

최고의 수영장 장비 제조업체 - 풀킨은 혁신적인 경영과 탁월한 품질을 위해 계속 노력할 것입니다. 상상력이 미래를 뒤집고, 지능형 제조가 시대를 선도할 것입니다. 이것이 풀킹의 모토입니다!

질문이 있으시면 저희에게 연락해 주세요.

연락처: 샌디

이메일: sandy@poolking.co

영업 핫라인: +86-20-34982303

왓츠앱:+86-13922334815

추가: 아니요. 광저우시 난사구 다강진 다강촌 다난북로 80호 (임시 영업소)

저작권 © 2025 광동 풀킹 여과 장비 제조 유한회사 유한회사 - www.poolking.co 모든 권리는 보호됩니다. | 사이트맵
문의하기
whatsapp
고객 서비스에 문의하십시오
문의하기
whatsapp
취소
Customer service
detect